MAIN MENU → CONFIGURATION → SCHEDULING OPTIMIZATION → VRP PROCESS
AOCEOPTSCHEDMINAVAIL: minimum resource residual availability for Post-VRP optimization and for optimization and integration
AOCEOPTADDEDACTIVITYCOUNT: minimum number of tasks assigned for Post-VRP optimization and for optimizing and integrating
AOCEOPTSPACTIVITYCOUNT: number of activities taken from the TSP activity upload task for the optimization and integration process for resources;
AOCEOSSOVERTIME: overtime minutes allowed for the operational resources on the branch/operating center; default = 0 min.
AOCEISDAILYFREEZING: daily freezing flag. It allows to change (paste, remove) scheduling in the past. Values: 0, 1. If the value is equal to 1, no changes are allowed (in past and future days).
AOCEFREEZINGDAYS: Enable only if AOCEISDAILYFREEZING equal 0. Therefore, if AOCEISDAILYFREEZING equal to 0, this parameter allows to define the total number of scheduling days that can be changed (paste, remove). The parameter includes positive and negative values. Positive values lock changes, while Negative values unlock changes. Examples:
1 --> scheduling changes on current day are locked
2 --> scheduling changes on current day and tomorrow are locked
0 --> no scheduling changes are allowed in past time, but changes are allowed in future time
-1 --> scheduling changes on yesterday are allowed
-365 --> all scheduling changes related last year are allowed
AOCEFREEZINGTIME: Enable only if AOCEISDAILYFREEZING equal 0. Therefore, if AOCEISDAILYFREEZING equal to 0, this parameter allows to define a time limit on allowed changes Default value: 01/01/1970 23:59:00.
AOCEISTEAMSUGGESTIONENABLED: Team Suggestion flag to enable AI module
AOCEISDURATIONPREDICTIONENABLED: Flag to enable Duration prediction AI feature
MAXVRPMULTISTAGEGROUPS: Number of tasks to consider in the MST building
AOCEISCALCTIMEDISTANCEOSS: it allows to call the SearchPath with Paste functionality and to compute the travel time between assignments - replaced by “Flag to disable distance calculation” in System Settings;
AOCEISREALTIME: it allows to activate real time;
AOCERTDELTATIMEFROMSHIFTSTART: time interval to be considered for each technician work shift, in real time process All resources with work shift beyond the set time interval are excluded during real time processing;
AOCERTDELATTIMELASTINFO: maximum delta time, within which the technician is taken into consideration in real time process. This value is compared with the last syncro - property AUSELASTSYNCDATE in the Table AUSER;
AOCERTNOREMOVEAAAGECOUNT: number of activities to not remove from the single technician, in real time processing;
AOCERTNOREMOVEAAAGEDELTATIME: delta time to consider for not removable activities, in real time processing. It is considered in addition to ‘AOCERTNOREMOVEAAAGECOUNT’ parameter;
AOCERTDELTATIMEPLANRESTART: in real time processing, the start of the day is set as the current time plus the delta indicated in this parameter. It allows the technician to have time to leave for the new schedule.